• en-GBfr-FRsv-SEde-DE

  |  News  | Videos  |  Downloads  |  Careers  |  Contact  |

Technical Specifications - Granule Maxi

Granule Maxi is a frontloaded granule utensil washer available as compact solution with retractable loading cassette, or as flexible system with one or more cassettes and trolleys. Customize with one or more smart accessories to accomodate an wash almost any kitchen utensil.

GENERAL.

Design Compact Edition / Flow Edition / FreeFlow Edition
Outer dimensions
(H x W x D)
2,039 mm x 1,452 mm x 1,089 mm
Loading volume 450 litres (B 540 x H 1,060 x D 680 mm)
Weight (filled / empty) 666 kg / 485 kg
Wash tank volume
165 liters
Rinse water volume
7 litres (ECO programme) 14 litres (Short / Normal programme)
To achieve 3,600 HUE in accordance with NSF/ANSI 3, 14 litres is necessary.
Granule volume
16 liters
Wash water temperature 65 °C
Rinse water temperature
85 °C
Sound pressure level
<70 dB(A)

PROGRAMMES & CAPACITY.

Wash programmes with Granules
ECO: 2 min, 30 sec
Short: 4 min, 40 sec**
Normal: 6 min, 40 sec**
Wash programmes without Granules ECO: 2 min, 30 sec
Short: 3 min, 40 sec **
Normal: 5 min, 40 sec **
Max. / normal capacity per hour (normal capacity incl. handling) 192/136 (Compact) / 192/144 (Flow) / 192/160 (FreeFlow)
Capacity per programme 8 GN1/1 or up to 16 GN1/2 or 4 GN2/1, up to 200 mm depth or similar in other pots.

WATER CONNECTION.

Hot water ½" (DN15), 55–65 °C, 3–10 °dH
Note: Reverse osmosis water and distilled water must not be used.
1–6 bar, 25 litres per minute
Cold water ½" (DN15), 3–10 °dH
3–6 bar, 15 litres per minute.

ELECTRICAL CONNECTION.

Voltage 3~ 208 V/60 Hz + PE - prepared for CSA approval
3~ 230 V/50 or 60 Hz + PE
3~ 400 V/50 or 60 Hz + PE
3~ 415 V/50 Hz + PE
3~ 440 V/60 Hz + PE
3~ 575 V/60 Hz + PE - prepared for CSA approval
Fuses (hot water connection) 32A (575V) / 40A (400V, 415V) / 63A (208 V, 230V)
Fuses (cold water connection) 50A (380V, 400V, 415V)
Fuses, steam heated, 0,3-2,0 bar 20A (400V) / 25A (230V)
Max output, hot water connection 21 kW
Max output, cold water connection 29 kW
Wash pump motor 2 x 2.2 kW
Rinse pump motor 0.37 kW
Wash tank element* 16 kW (24 kW cold water connection)
Rinse tank element* 16 kW (24 kW cold water connection)
Enclosure rating IPX5

DRAIN & VENTILATION.

Ventilation recommendation
with steam reduction

300 m3/h
Ventilation recommendation
without steam reduction

900 m3/h
Ventilation recommendation
with EcoExchanger

150 m3/h
Heat load to room with steam reduction (total/sensible/latent)
2.7 kW / 1.0 kW / 1.7 kW
Heat load to room without steam reduction (total/sensible/latent)
4.9 kW / 1.0 kW / 3.9 kW
Heat load to room with EcoExchanger (total/sensible/latent)
2.0 kW / 1.0 kW / 1.1 kW
Drainage pipe Pipe Ø 32 mm
Capacity requirement 50 l/min
The machine must not be placed directly over a drain.
Detergent and drying agent are required Detergent and drying agent; 230 VAC signal is available from a separate box. Max load total 0.5 A

 

* Does not operate simultaneously.
** 1 min longer with steam reduction.

Granule Maxi is supplied with a 2-metre-long power cable (without plug) for connection to an approved mains switch. The mains switch is not included in the delivery.

 

STEAM REDUCTION OR ECOEXCHANGER?


Granule Maxi is standard fitted with steam reduction, which serves for a more pleasant working environment for staff and lowers the ventilation requirements in the pot wash area.

EcoExchanger is an optional add-on that cleverly combines steam reduction and heat recovery in one. Improves the working environment and saves up to 33% of the energy needed for heating the wash tank.

 

Talk to your GRANULDISK sales representative or your preferred Certified GRANULDISK Sales Partner for more information about steam reduction and EcoExchanger for Granule Maxi.

 


MARINE OPTION.


Installing Granule Maxi in an offshore operation? Ensure steady operation and safe use with the Marine Option:

  • double level sensors in the wash tank
  • feet that can be bolted to the floor to prevent sliding or tipping
  • door stops to prevent doors swinging

 

Talk to your GRANULDISK sales representative or preferred Certified GRANULDISK Sales Partner about the Marine Option.

 


INSTALLATION DRAWING.

Zoom: right-click and open image in new tab.

(A) Hot water inlet, 55–65 °C, 3–10 °dH, 5–18 °f. 1–6 bar, 15 L/min, max. 6 bar static. G ½” BSP female, flexible hose min. inner Ø 9 mm. (B) Cold water inlet, 3–10 °dH, 5–18 °f. 3–6 bar, 15 L/min, max. 6 bar static. G ½” BSP female, flexible hose min. inner Ø 9 mm. (C) Drain. (D) Detergent/drying agent connection, signal 230V AC. (E) Electrical connection. (F) USB port.

--- EcoExchanger unit - optional add-on, combined heat recovery and steam reduction. NB: The EcoExchanger unit must be connected to a cold water feed at all times (B). EcoExchanger is only available for cold water option machines (max power 50A, 29 kW) but on site, the machine can be connected to either a hot or a cold water feed (A/B). EcoExchanger is to be fitted on site, after installation of pot washer.

--- Only relevant to Granule Maxi Flow/FreeFlow Editions.