• en-GBfr-FRsv-SEde-DE

  |  News  | Videos  |  Downloads  |  Careers  |  Contact  |

Technical Specifications - Granule Smart

Granule Smart is one of our most compact machines ever, needing less than 1 m2 floor space and 2,026 mm height. The standalone design requires no extra tables or benches as the lower door hatch folds down and doubles as a built-in loading table for the basket.

GENERAL.

Design Standard Edition / FreeFlow Edition
Outer dimensions
(H x W x D - door open)
2,026 mm (± 25) x 1,025 mm x 1,314 mm
Loading volume 220 litres (Ø 700 mm x H 570 mm)
Weight (filled / empty) 381 kg / 257 kg
Wash tank volume
108 liters
Rinse water volume
4 litres (ECO programme) 6 litres (Short / Normal programme)
To achieve 3,600 HUE in accordance with NSF/ANSI 3, 6 litres is necessary.
Granule volume
8 liters
Wash water temperature 65 °C
Rinse water temperature
85 °C
Sound pressure level
<70 dB(A)

PROGRAMMES & CAPACITY.

Wash programmes with Granules
ECO: 2 min
Short: 3 min**
Normal: 5 min**
Wash programmes without Granules ECO: 2 min
Short: 2 min, 30 sec **
Normal: 4 min, 30 sec **
Max. / normal capacity per hour (normal capacity incl. handling) Standard Edition: 180 / 132 GN1/1 or similar in other pots
FreeFlow Edition: 180 / 156 GN1/1 or similar in other pots
Capacity per programme 6 GN1/1 65 mm depth or 3 GN1/1 up to 200 mm depth and 3 GN1/1 up to 65 mm depth, or similar in other pots.

WATER CONNECTION.

Hot water ½" (DN15), 55–65 °C, 3–10 °dH
Note: Reverse osmosis water and distilled water must not be used.
1–6 bar, 15 litres per minute
Cold water ½" (DN15), 3–10 °dH
1–6 bar, 15 litres per minute. 3-6 bar with optional steam reduction

ELECTRICAL CONNECTION.

Voltage 3~400 V/50 Hz + PE
3~415 V/50 Hz + PE
3~230 V/50 Hz + PE
3~440 V/60 Hz + PE
3~208 V/60 Hz + PE - prepared for CSA approval
Fuses (hot water connection) 25A (400 V, 415 V, 440 V) / 40A (230 V) / 50A (208 V)
Fuses (cold water connection) 32A (400 V, 415 V)
Max output, hot water connection 11.5 kW
Max output, cold water connection 16.5 kW
Wash pump motor 2.2 kW
Rinse pump motor 0.11 kW
Wash tank element* 9 kW (14 kW cold water connection)
Rinse tank element* 9 kW (14 kW cold water connection)
Enclosure rating IPX5

DRAIN & VENTILATION.

Ventilation recommendation
with steam reduction

200 m3/h
Ventilation recommendation
without steam reduction

500 m3/h
Ventilation recommendation
with EcoExchanger

100 m3/h
Heat load to room with steam reduction (total/sensible/latent)
1.7 kW / 0.8 kW / 0.9 kW
Heat load to room without steam reduction (total/sensible/latent)
2.4 kW / 0.8 kW / 1.6 kW
Heat load to room with EcoExchanger (total/sensible/latent)
1.3 kW / 0.8 kW / 0.5 kW
Drainage pipe Pipe Ø 32 mm
Drain Capacity requirement 50 l/min
The machine must not be placed directly over a drain.
Detergent and drying agent are required Detergent and drying agent; 230 VAC signal is available from a separate box. Max load total 0.5 A

 

* Does not operate simultaneously.
** 30 secs longer with steam reduction.

Granule Smart is supplied with a 2-metre-long power cable (without plug) for connection to an approved mains switch. The mains switch is not included in the delivery.

STEAM REDUCTION OR ECOEXCHANGER?


With the add-on steam reduction to your Granule Smart, you ensure a more pleasant working environment for staff and lower the ventilation requirements.

The add-on EcoExchanger cleverly combines steam reduction and heat recovery in one and improves the working environment, while also reducing energy needed for heating the wash tank by up to 40%.

 

Talk to your GRANULDISK sales representative or your preferred Certified GRANULDISK Sales Partner for more information about steam reduction and EcoExchanger for Granule Smart.


MARINE OPTION.


Installing Granule Smart in an offshore operation? Ensure steady operation and safe use with the Marine Option:

  • double level sensors in the wash tank
  • feet can be bolted to the floor to prevent sliding and tipping

 

Talk to your GRANULDISK sales representative or your preferred Certified GRANULDISK Sales Partner for more information about the Marine Option.

 


INSTALLATION DRAWING.

Zoom: right-click picture and open in new tab.


(A) Water inlet, 55–65 °C (cold water optional), 3–10 °dH, 5–18 °f. 1–6 bar, 15 L/min, max. 6 bar static. G ½” BSP female, flexible hose min. inner Ø 9 mm. (B/E) Detergent/drying agent connection, signal 230V AC. (C) Electrical connection. (D) Drain. (F) Cold water inlet (if steam reduction / EcoExchanger). (G) USB port.

--- EcoExchanger unit (optional add-on). The EcoExchanger unit (heat recovery and steam reduction) must be connected to a cold water feed at all times.(F) Note: EcoExchanger is only available for cold water option machines (max power 32A, 16,5 kW) but on site, the machine can be connected to either a hot or a cold water feed. (A)
--- Wash Basket Trolley x 2 (FreeFlow Edition only).